Chapter 6 Operations and Measurements RIGOL
MSO8000 User Guide 6-49
âš« AX: indicates the X value at Cursor A.
âš« AY: indicates the Y value at Cursor A.
âš« BX: indicates the X value at Cursor B.
âš« BY: indicates the Y value at Cursor B.
âš« â–³X: indicates the horizontal spacing between Cursor A and Cursor B.
âš« â–³Y: indicates the vertical spacing between Cursor A and Cursor B.
âš« 1/â–³X: indicates the reciprocal of the horizontal spacing between Cursor A and
Cursor B.
1. Select Measurement Source
âš« Press AX Source, then rotate the multifunction knob to select the
desired measurement source. Press down the knob to select it. You can also
press AX Source continuously or enable the touch screen to select it. The
available source channels are None, CH1-CH4, and Math1-Math4.
âš« Press BX Source, then rotate the multifunction knob to select the
desired source (CH1-CH4). Press down the knob to select it. You can also
press BX Source continuously or enable the touch screen to select it. The
available source channels are None, CH1-CH4, and Math1-Math4.
Note: Only channels currently enabled can be selected.
2. Select the Track Axis
Press Track to select "X" or "Y" as the current track axis. The default is "X".
âš« X: tracks X Cursor and measures the value at X Cursor.
âš« Y: tracks Y Cursor and measures the time of the first point at the left side of
the screen.
3. Adjust Cursor Position
1) When "X" is selected under Track, you can adjust the position of X cursor.
âš« Press AX, then rotate the multifunction knob to adjust the
horizontal position of Cursor A (X cursor). Its adjustable range is
limited within the screen.
âš« Press BX, then rotate the multifunction knob to adjust the
horizontal position of Cursor B (X cursor). Its adjustable range is
limited within the screen.
âš« Press AX BX, then rotate the multifunction knob to adjust the
horizontal position of Cursor A and Cursor B (X cursors) simultaneously.
Its adjustable range is limited within the screen. The horizontal spacing

Table of Contents

Other manuals for Rigol MSO8000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO8000 Series and is the answer not in the manual?

Rigol MSO8000 Series Specifications

General IconGeneral
BrandRigol
ModelMSO8000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals