Rigol MSO5074 - User Manual

Rigol MSO5074
372 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Guide
MSO5000 Series Digital
Oscilloscope
May. 2020
RIGOL TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Rigol MSO5074

Questions and Answers

  • M
    mcdonaldoscarAug 9, 2025
    What to do if Rigol Test Equipment stays black after power on?
    • D
      Derrick RussellAug 9, 2025
      If your Rigol Test Equipment's screen remains black after powering it on, verify that the power switch is turned on and the power cord is correctly connected. Also, check the fuse and replace it if necessary with the specified type. After these checks, restart the equipment. If the issue continues, it may require professional assistance.
  • E
    elizabeth24Aug 16, 2025
    Why Rigol MSO5074 Test Equipment doesn't recognize USB storage device?
    • C
      courtney71Aug 16, 2025
      If your Rigol Test Equipment is not recognizing the USB storage device, first ensure that the USB device works correctly. Confirm that the USB storage device uses FAT32-format Flash storage. The equipment does not support hardware storage types. Check that the USB storage device's capacity does not exceed 8 GB. Try restarting the instrument with the USB device inserted. If problems persist, further assistance may be needed.
  • C
    Clinton CarrollAug 25, 2025
    What to do if touch functions don't work on Rigol MSO5074?
    • T
      Troy HessAug 25, 2025
      If the touch functions are not working correctly on your Rigol Test Equipment, first verify that the touch screen is enabled by pressing the Touch Lock switch. Ensure that the screen and your fingers are clean and free of oil or sweat. Check for any strong magnetic fields near the instrument, and if present, move the instrument away from the magnetic source. If the issue persists, further assistance may be required.
  • S
    Stephanie OrtegaAug 31, 2025
    Why is the waveform display ladder-like on Rigol MSO5074 Test Equipment?
    • J
      Joshua StewartAug 31, 2025
      A ladder-like waveform display on your Rigol Test Equipment can occur if the horizontal time base is too low. Increasing the horizontal time base should improve the display. Also, if the display type is set to 'Vector', switch to 'Dots' by pressing the Display Type button, as the lines between sample points in 'Vector' mode can cause this effect.

Summary

Safety Requirement

General Safety Summary

Overview of essential safety precautions before operating the instrument.

Safety Notices and Symbols

Explanation of safety symbols and terms used in the manual.

Chapter 1 Quick Start

Chapter 2 To Set the Vertical System

To Adjust the Vertical Scale

Setting the voltage per division for waveform display.

Chapter 3 To Set the Horizontal System

Chapter 4 To Set the Sample System

Chapter 5 To Trigger the Oscilloscope

Trigger Source

Selecting the signal source for triggering the oscilloscope.

Trigger LEVEL;Threshold Level

Setting the voltage level for triggering conditions.

Trigger Mode

Selecting between Auto, Normal, and Single trigger modes.

Trigger Type

Overview of various trigger types like Edge, Pulse, and Protocol.

Chapter 6 Operations and Measurements

Math Operation

Performing mathematical calculations (A+B, FFT, etc.) on waveforms.

Auto Measurement

Automatic measurement of waveform parameters like period and amplitude.

Cursor Measurement

Manual measurement of waveform parameters using cursors.

Chapter 7 Digital Voltmeter (DVM) and Frequency Counter

Chapter 10 Digital Channel

Chapter 11 Protocol Decoding

Parallel Decoding

Decoding signals on a parallel bus interface.

RS232 Decoding (Option)

Decoding serial data transmitted via RS232 protocol.

I2 C Decoding (Option)

Decoding serial data transmitted via I2C protocol.

SPI Decoding (Option)

Decoding serial data transmitted via SPI protocol.

LIN Decoding (Option)

Decoding serial data transmitted via LIN protocol.

CAN Decoding (Option)

Decoding serial data transmitted via CAN protocol.

Chapter 13 Pass;Fail Test

To Enable or Disable the Pass;Fail Test Function

Activating or deactivating the pass/fail test function.

To Create a Mask

Defining custom masks for pass/fail criteria.

Chapter 17 Function;Arbitrary Waveform Generator (Option)

Chapter 19 Bode Plot

Chapter 21 Remote Control

Remote Control via USB

Establishing remote control connection using a USB interface.

Remote Control via LAN

Establishing remote control connection using a LAN interface.

Remote Control via GPIB

Establishing remote control connection using a GPIB interface.

Chapter 22 Troubleshooting

No waveform of the signal is displayed on the screen.

Steps to resolve issues where no signal waveform is shown.

Rigol MSO5074 Specifications

General IconGeneral
Bandwidth70 MHz
Channels4
Timebase Accuracy± 2 ppm
Operating Temperature0 °C to +40 °C
Display800x480
Waveform Capture Rate500, 000 wfms/s
Vertical Resolution8 bits
InterfacesUSB Host, USB Device, LAN, HDMI
Input Impedance1 MΩ
Trigger TypesEdge, Slope, Pulse, Video, Pattern, Duration, Timeout, Window, Runt
Sample Rate8 GSa/s