User Guide
MSO7000/DS7000 Series Digital
Oscilloscope
Jul. 2020
RIGOL TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Rigol MSO7024

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO7024 and is the answer not in the manual?

Rigol MSO7024 Specifications

General IconGeneral
BrandRigol
ModelMSO7024
CategoryTest Equipment
LanguageEnglish

Summary

Safety Requirement

General Safety Summary

Provides essential safety precautions for instrument operation to prevent injury and damage.

Safety Notices and Symbols

Explains warning and caution notices and common safety symbols used in the manual and on the product.

Chapter 1 Quick Start

Chapter 2 To Set the Vertical System

To Adjust the Vertical Scale

Explains how to adjust the vertical scale (Volts/division) for accurate waveform amplitude display.

Chapter 3 To Set the Horizontal System

To Adjust the Horizontal Time Base

Guides users on setting the horizontal time scale (seconds/division) to view waveform details effectively.

Chapter 4 To Set the Sample System

Acquisition Mode

Details the four acquisition modes: Normal, Average, Peak, and High Resolution for waveform sampling.

Chapter 5 To Trigger the Oscilloscope

Trigger Source

Details how to select trigger sources, including analog, digital, external, and AC line inputs.

Trigger Mode

Explains the different trigger modes (Auto, Normal, Single) for capturing stable waveforms.

Chapter 6 Operations and Measurements

Math Operation

Describes how to perform mathematical operations (Add, Subtract, FFT, Logic) on waveforms.

Auto Measurement

Explains how to automatically measure waveform parameters like period, frequency, and rise time.

Cursor Measurement

Guides users on using cursors to manually measure time and voltage parameters of waveforms.

Chapter 7 Digital Voltmeter (DVM) and Frequency Counter

Chapter 10 Digital Channel

Chapter 11 Protocol Decoding

Chapter 13 Pass/Fail Test

To Create a Mask

Guides users on defining custom masks for pass/fail testing of waveforms.

Chapter 17 Function/Arbitrary Waveform Generator (MSO7000 Option)

Chapter 18 Store and Load

Factory Settings

Explains how to restore the oscilloscope to its default factory configuration.

Chapter 20 Remote Control

Remote Control via USB

Provides instructions for establishing remote control using a USB connection and installing drivers.

Chapter 21 Troubleshooting

The instrument cannot be launched normally

Offers solutions for common issues preventing the instrument from powering on or starting correctly.

The touch functions cannot be used normally

Provides troubleshooting steps for unresponsive or malfunctioning touch screen functionality.

Related product manuals