EasyManua.ls Logo

Rinnai FS35 ETR - User Manual

Rinnai FS35 ETR
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Flame Fire ETR
Electronic Timer and Remote
Operating and Installation Instructions
Freestanding Royale ETR (Australia)
Timberflame FS35 ETR (New Zealand)
Table of Contents
Customer Instructions
Control Panel Layout 2
Operation 3
Setting the Clock 5
Operating the Timers 6
Error Codes 7
Safety Points 8
Troubleshooting 9
Installation Instructions
Location 10
Flueing 11
Gas Connection 11
Log Installation 12
Testing & Commissioning 13
Technical Data 14
Service Contact Points 14
Wiring Diagram 15
Installation Checklist 16
Installer Details 16
IMPORTANT
This appliance shall be installed in accordance with:
Manufacturers Installation Instructions.
Local Gas fitting regulations.
Municipal Building codes.
Gas Installation Code AG5601 / AG601 - NZ 5261.
Any other relevant statutory regulation.
This appliance must only be installed, serviced and removed by an
authorised person.
For Australian installation, this appliance must be installed with
the supplied wire dressguard.

Questions and Answers

  • D
    Daniel CardenasJul 31, 2025
    Why Rinnai Indoor Fireplace burner will not light?
    • D
      Dr. Eric Cole MDJul 31, 2025
      The burner of your Rinnai Indoor Fireplace might not light due to several reasons. It could be due to no power present; ensure the power cord is plugged in and turned on. Another reason could be no gas present; ensure the gas supply is turned on. It could also be due to a power cut; re-ignite after power is restored. Air in the gas pipe may also be a factor, in which case you should purge the air. Finally, it could be due to an ignition failure; repeat the lighting procedure.
  • W
    William JosephAug 10, 2025
    What to do if I smell gas from my Rinnai Indoor Fireplace?
    • B
      Briana JohnsonAug 11, 2025
      If you smell gas from your Rinnai Indoor Fireplace, it could be due to a gas leak. Immediately turn off the gas at the meter and call your installer.
  • D
    David KimAug 21, 2025
    How to fix Rinnai Indoor Fireplace fan not working?
    • J
      jamessullivanAug 21, 2025
      If the fan in your Rinnai Indoor Fireplace isn't working, it could be that the heat switch hasn't been activated. Allow the heater to run on HIGH for at least 15 minutes. Alternatively, the fan might not be turned on; make sure the appliance fan switch is in the ON position.

Summary

Control Panel Layout

Operation

Error Codes

Error Code Interpretation

List of error codes, probable causes, and recommended actions for troubleshooting.

Safety Points

General Safety Precautions

Important safety warnings and guidelines for using the heater safely.

Troubleshooting

Common Symptoms and Solutions

Guide to identifying and resolving common symptoms with their causes and solutions.

Flueing

Gas Connection

Testing and Commissioning

Installation and Commissioning Procedures

Includes testing, commissioning, checklist completion, and customer instructions.

Wiring Diagram

Installation and Installer Information

Rinnai FS35 ETR Specifications

General IconGeneral
ModelFS35 ETR
CategoryIndoor Fireplace
TypeDirect Vent Gas Fireplace
Fuel TypeNatural Gas or Propane
VentingDirect Vent
IgnitionElectronic Ignition

Related product manuals