Gas Continuous Flow Water Heater
Operation & Installation Manual
MODELS
Infinity 32 (REU-AM3237W)
HD32e (REU-AM3237WC)
Infinity 26 Touch (REU-AM2626WDL)
Infinity 26 (REU-AM2626WD)
Infinity 20 (REU-AM2024WD)
Infinity 16 (REU-AM1620WD)
Infinity 12 (REU-AM1220WD)
Infinity Enviro 26 (REU-E2626W)
Infinity Enviro 16 (REU-E1620W)
Infinity 28i (REU-VCM2837FF)
HD28i (REU-VCM2837FFC)
HD28e (REU-VCM2837WC)
B26 (REU-A2626WB)
B20 (REU-A2024WB)
B16 (REU-A1620WB)

Table of Contents

Questions and Answers

  • R
    robinsonsheriSep 2, 2025
    What to do if Rinnai HD32e does not start?
    • C
      cordovaericSep 2, 2025
      If your Rinnai Water Heater isn't starting, make sure the power is on at the unit and check that the isolation valves are open.
  • J
    Joshua HolmesSep 14, 2025
    How to fix noticeable reduction in water flow in Rinnai HD32e Water Heater?
    • L
      Linda JonesSep 14, 2025
      If you notice a reduction in water flow in your Rinnai Water Heater, the inlet water filter may need cleaning. It is recommended to request a service call.
  • C
    Catherine MaloneAug 31, 2025
    How to fix Rinnai HD32e no ignition/no gas supply?
    • S
      Stacie HoltAug 31, 2025
      If your Rinnai Water Heater won't ignite due to a potential lack of gas supply, first, verify that the gas is turned on both at the water heater itself, and at the gas meter or cylinder.
  • S
    Stacy SmithSep 16, 2025
    What to do if Combustion Fan Failure in Rinnai HD32e Water Heater?
    • S
      Stefanie GreerSep 16, 2025
      If there is a Combustion Fan Failure in your Rinnai Water Heater, it is recommended to request a service call.
  • D
    Daniel GeorgeSep 15, 2025
    What to do if Gas Modulating Valve is Faulty in Rinnai HD32e Water Heater?
    • D
      dtoddSep 15, 2025
      If the Gas Modulating Valve in your Rinnai Water Heater is faulty, it is recommended to request a service call.
  • D
    Dr. Judith CantrellSep 23, 2025
    How to check for condensate pipe blockage in Rinnai HD32e Water Heater?
    • M
      Michael MooreSep 23, 2025
      If you suspect a condensate pipe blockage in your Rinnai Water Heater, check the condensate drain path for any obstructions.
  • M
    mezaarthurAug 27, 2025
    What to do if Rinnai HD32e starts then shuts down immediately?
    • M
      maryschmidtAug 28, 2025
      If your Rinnai Water Heater starts and then immediately shuts down, verify that the power is still on. Also, check that the gas valve at the unit and the gas meter are fully open. Ensure that your hot water tap is fully open as well.
  • C
    Christopher MillerAug 27, 2025
    What to do if there is a power interruption during bath fill with my Rinnai HD32e Water Heater?
    • K
      Karen JensenAug 27, 2025
      If there's a power interruption during a bath fill and water won't flow on power reinstatement with your Rinnai Water Heater, turn off all hot water taps and press the On/Off button twice.
  • K
    kmendezAug 26, 2025
    Why does my Rinnai HD32e Water Heater start and then the water goes cold?
    • D
      Dr. Cody GomezAug 27, 2025
      If your Rinnai Water Heater starts and then the water goes cold, verify that the power is still on. Also, try opening your hot water tap further.
  • K
    Karen RogersAug 25, 2025
    What to do if my Rinnai HD32e Water Heater starts then the water goes cold?
    • M
      Melissa GriffinAug 26, 2025
      If your Rinnai Water Heater starts but the water goes cold, verify that the power is still on. Additionally, try opening your hot water tap further.

Rinnai HD32e Specifications

General IconGeneral
ModelHD32e
CategoryTankless Water Heater
Fuel TypeNatural Gas
GPM at 35°F Rise3.2 GPM
Temperature Range98°F - 140°F
Venting Size3"
Electrical Requirements120 VAC
Ignition TypeElectronic