EasyManua.ls Logo

Rinnai Titan MkII - User Manual

Rinnai Titan MkII
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GRADUATE MkII / TITAN MkII
GALAXIE MkII / GRANADA MkII
UNFLUED
with hose
CUSTOMERS OPERATING
INFORMATION
AND
INSTALLATION INSTRUCTIONS
This appliance shall be installed in accordance with:
l Manufacturer’s Instructions
l Local Authority Building Codes
l NZS 5261 Installation Code for Gas Burning Equipment
l Any other relevant Statutory Regulation
This appliance must be installed, serviced and removed by
an authorised person.
.
RiMai
GAS SPACE HEATERS
Question and Answer IconNeed help?

Do you have a question about the Rinnai Titan MkII and is the answer not in the manual?

Summary

Safety Devices

Oxygen Depletion Sensor Safety

System turns heater off if room oxygen level falls below a pre-set safety level.

Flame Failure Device Function

Device automatically cuts off gas supply if the flame extinguishes during operation.

Tilt Switch Safety

Cuts off gas supply if the heater is accidentally knocked over.

Important Points - Safety and Usage

Important Points - Restrictions and Warnings

Pre-Service Check and Fault Finding

Troubleshooting Common Issues

A chart to help identify and resolve common heater problems before service calls.

Installation Instructions

Customer Operation - Ignition and Controls

Customer Operation - Heat, Fan, and Shutdown

Overview

The Rinnai Graduate MkII / Titan MkII / Galaxie MkII / Granada MkII is an unflued, fan-assisted, radiant/convection gas space heater designed for efficient room heating. It operates on either Natural Gas or Propane, depending on the specific model and region.

Function Description:

This appliance functions as a flueless space heater, meaning it does not require a flue or chimney for operation. It utilizes both radiant heat from its jewel cut plaque burner and convection heat, circulated by a large capacity fan, to warm the room effectively. The heater features electronic automatic ignition for ease of use and a push-button, top-mounted control panel for managing its operation.

Important Technical Specifications:

  • Models and Heat Output (Input):
    • REH-151UCH (Titan MkII): Propane 14 MJ/h / Natural 15 MJ/h
    • REH-181UCH (Graduate MkII): 18 MJ/h
    • REH-212UCH (Galaxie MkII): 21 MJ/h
    • REH-252UCH (Granada MkII): 25 MJ/h
  • Gas Control: Rinnai Push Button Combination Control.
  • Burner: Rinnai Jewel Cut Plaque.
  • Gas Inlet: Supplied with an approved 1.5 m hose.
  • Ignition: Electronic.
  • Oxygen Depletion System (ODS): Rinnai ODS Pilot.
  • Power Supply: 230 V 50 Hz, supplied with a 3-pin plug and supply lead (Rinnai part number 3010 for replacement).
  • Fan: Tangential, 2-speed, 24 Watt Rating.
  • Data Plate: Located at the rear, near the gas connection.
  • Minimum Room Size Requirements (m³):
    • Titan MkII (REH-151UCH): 75 m³ (WA: 37.5 m³)
    • Graduate MkII (REH-181UCH): 90 m³ (WA: 45 m³)
    • Galaxie MkII (REH-212UCH): 105 m³ (WA: 52.5 m³)
    • Granada MkII (REH-252UCH): 125 m³ (WA: 62.5 m³)
  • Clearances: 150 mm from sides and top, 1000 mm from the front.
  • Dimensions (approximate):
    • Width: 620 mm
    • Height: 541 mm
    • Depth (Titan): 265 mm
    • Depth (Graduate/Galaxie/Granada): 240 mm
    • Rear Depth (Titan): 293 mm
    • Rear Depth (Graduate/Galaxie/Granada): 192 mm

Usage Features:

  • Easy Operation: Push-button, top-mounted controls for ignition and heat settings.
  • Electronic Automatic Ignition: Simplifies the start-up process.
  • Fan Control: Two-setting fan control (High/Low) and an OFF position, allowing users to match fan speed to heat output for maximum comfort. The fan starts automatically when the heater is alight and stops when turned off.
  • Power Failure Operation: The heater can be used during a power failure, indicating a manual or battery-powered ignition system for basic operation.
  • Heat Settings:
    • Increasing Heat: Press control buttons from front to rear to ignite additional burners. No need to hold buttons for 15 seconds when increasing heat.
    • Decreasing Heat: Release control buttons from rear to front to the desired setting.
    • Burner Settings (MJ/h):
      • Titan: LOW 7, Natural HIGH 15, Propane HIGH 14
      • Graduate: LOW 6, MEDIUM 12, HIGH 18
      • Galaxie: LOW 7, MEDIUM 14, HIGH 21
      • Granada: LOW 8, MEDIUM 16, HIGH 25
  • Safety Devices:
    • Oxygen Depletion Sensor (ODS): Automatically shuts off the heater if oxygen levels in the room fall below a pre-set level, often due to lack of ventilation or use in too small a room. Ventilation is required before relighting.
    • Flame Failure Device: Cuts off the gas supply if the flame is extinguished during operation.
    • Tilt Switch: Cuts off the gas supply if the heater is knocked over, jolted, or picked up while in operation. To restore, stand the heater upright and follow the ignition procedure.
    • Guard: Fitted to reduce the risk of fire or injury from burns. A secondary guard is required for the protection of young children or the infirm.
  • Hose Retaining Clips and Cord Storage Holder: For tidy management of connections.
  • Installation Requirements: Must conform to local regulations, manufacturer's instructions, local authority building codes, NZS 5261 Installation Code for Gas Burning Equipment, and any other relevant statutory regulations. An earthed power point and bayonet gas connection must be close enough to avoid stretching connections.
  • Important Usage Restrictions:
    • Do not use for any purpose other than heating.
    • Maintain specified clearances (150 mm sides/top, 1000 mm front).
    • Do not allow curtains or flammable materials to contact the heater.
    • Do not store flammable products near the heater.
    • Do not place combustible materials where the heater could ignite them.
    • Do not allow young children or the infirm to sleep directly in front of the heater.
    • Supervise children near the heater.
    • Do not allow children to "post" articles in the louvres.
    • Do not place articles containing liquid on top of the heater.
    • Do not spray aerosols in the vicinity of the heater while it is in operation, as they can cause unpleasant smells and be a fire hazard.
    • Do not sit on the heater or place articles on or against it.
    • Do not use in areas where spray painting, or high levels of fluff, dust, or aerosols are present (e.g., hairdressers).
    • Not designed to be built into bookcases or shelves.

Maintenance Features:

  • Low Maintenance: Requires very little maintenance to keep it looking good and working efficiently.
  • Outer Case Cleaning: Clean with a soft, damp cloth. Do not use aerosol polishes on the casing while the heater is in operation. Do not clean plastic parts with solvents.
  • Oxygen Depletion Sensor Cleaning: Annual cleaning of the ODS is recommended, to be carried out by Rinnai or their agent.
  • Service and Removal: Must be installed, serviced, and removed by an authorised person.
  • Fault Finding Chart: A pre-service checklist and fault-finding guide is provided to help users troubleshoot common issues before requesting a service call, potentially avoiding chargeable service calls for normal operation.
  • Guarantee: Covered by a 2-year guarantee: free parts and labour for the first year, and parts only for the second year. This is in addition to consumer guarantees under the Consumer Guarantees Act.

Rinnai Titan MkII Specifications

General IconGeneral
BrandRinnai
ModelTitan MkII
CategoryGas Heater
LanguageEnglish

Related product manuals