Installation and Programming Manual 3-45
4) Code Maintenance
The Pro-24 supports up to 99 unique User Codes (known by a number from “00” through “98”)–each of which can
identify different system users–either to the Central Station (if Opening and Closing Reports are utilized), or to
those with the need to view the system’s Event Log (see the Pro-24 User’s Manual for details) to determine system
activities.
The User Codes, themselves, may be set by any individual(s) with the authority to do so by utilizing a mode called
User Functions (see the Pro-24 User’s Manual for details). As such, the actual numbers comprising most codes
need not be known to the alarm company.
Additionally, each User Code must be linked to one of six Authority Levels. Unlike the process of determining the
codes themselves, Authority Levels are assigned through the Installer Programming Mode, and will be detailed in
this section.
Table 3-4 describes names each Authority Level and describes the “accessibility” it provides:
AUTHORITY LEVEL DEGREE OF ACCESS GENERAL COMMENTS
Grand Master
arming and disarming
bypassing zones
access to all partitions
viewing system status, trouble, alarm
memory, and Event Log(s)
deleting Event Log(s) contents
changing the Grand Master’s Code
assigning, deleting, and changing
other User Codes
setting the system’s Time and Date
setting schedules for automatic
arming and disarming
resetting the Switched Auxiliary
Output
activating designated Utility Outputs
control of “Follow Me” activities and
its dialing process
specific control of
upload/downloading activities
administering system tests, including
Walk Testing
control of keypad sounds
there may be only one
Grand Master code in the
system
the Grand Master code is
designated as Code 00
only the Grand Master
can change the Grand
Master code
Manager
all of the above, except
:
changing the Grand Master’s Code
performing Walk Testing
there may be only one
Manager code in the
system
the Manager code is
designated as Code 01
the Manager can change
all User Codes except
that of the Grand Master
Table 3-4: User Code Hierarchy