Installation and Programming Manual 3-55
DIALER: CONTROLS (cont’d)
Quick Key Item Default Explanation
CONTROLS (cont’d)
5 5 06 Call Save
*
NO if YES:
to reduce Central Station “traffic”, the system holds all
non-urgent events (e.g. opening/closing reports, test
transmissions) for up to 12 hours and sends them as a
group at a less busy, programmable (e.g. at night) time
(see Periodic Test) on page 3-61
if NO:
all events are sent as they occur
5 5 07 User Initiated Call
*
YES if YES:
in order for a remote Upload/Download session to take
place, a system’s user must initiate the process by
entering specific keypad commands in the User
Functions mode (see the Pro-24 User’s Manual)
if NO:
remote Upload/Download operations are possible
without requiring the user’s participation
5 5 08 Call Back U/D
*
YES if YES:
enables greater security for remote Upload/Download
operations by requiring the Pro-24 to call back the pre-
programmed telephone number (see Remote U/D Tel
No. on page 3-51) to which the Alarm Company’s
Upload/Download computer is connected
if NO:
the Alarm Company’s computer simply calls the
account for which Upload/Download operations are
desired
a subsequent callback to a designated number is not
required
5 5 09 Auto Batch
*
NO if YES:
use if unattended Upload/Download operations are
desired
the Upload/Download software has the capability of
downloading previously-programmed installation data
from the Alarm Company to an account if the call is
initiated by the account
by enabling Auto Batch (selecting YES), the Pro-24
will call the Alarm Company’s computer at
the time specified in U/D Test under Periodic Test
(see page 3-61)
for Auto Batch to work, the computer must:
be turned on
be connected to the telephone line
have its Upload/Download software loaded
for detailed information on Auto Batch, see the
Pro-24 Upload/Download Software Manual
if NO:
the Auto Batch mode is disabled
* Not for UL Installations
INSTALLER PROG:
5)DAILER ↓