Installation and Programming Manual 3-65
REPORT CODES: ACCESSORY TAMPER
Quick Key Item Default Explanation
6 3 ACCESSORY
TAMPER
---
used to report the codes generated when the
tamper switch on a system accessory (i.e. a
Keypad or Expansion Module) is violated
(or restored)
keypads have built-in tamper switches
many Expansion Modules (e.g. Utility Outputs
and Power Supplies) permit the connection of
an external tamper switch
press [ENTER] to begin
6 3 1
Keypad ---
addresses the tamper codes and their restorals given to
system keypad(s); press [ENTER]
6 3 1 1 Tamper --- press [ENTER] to begin
00 enter the keypad’s 2-digit physical I.D. (e.g. 01) and
the corresponding 2-digit report code used to
represent a tamper condition on the designated
keypad
6 3 1 2
Keypad Tamper
Restore
--- press [ENTER] to begin
00 enter the keypad’s 2-digit physical I.D. (e.g. 01) and
the corresponding 2-digit report code used to
represent the restoral-to-normal of the tamper
condition
6 3 2 Utility Output
Module
--- addresses the tamper codes and their restorals given to
Utility Output modules; press [ENTER]
6 3 2 1 Tamper --- press [ENTER] to begin
00 enter the UO’s 1-digit physical I.D. and the
corresponding 2-digit report code used to represent a
tamper condition on the designated Utility Output
module
6 3 2 2
Utility Output Module
Tamper Restore
press [ENTER] to begin
00 enter the UO’s 1-digit physical I.D. and the
corresponding 2-digit report code used to represent
the restoral-to-normal of the tamper condition
6 3 3 Power Supply Module ---
Addresses the tamper codes and their restorals given to
Power Supply modules; press [ENTER]
6 3 3 1 Tamper --- press [ENTER] to begin
00 enter the Power Supply’s 1-digit physical I.D. and the
corresponding 2-digit report code used to represent a
tamper condition on the designated Power Supply
module
6 3 3 2
Power Supply
Module Tamper
Restore
--- press [ENTER] to begin
00 enter the Power Supply’s 1-digit physical I.D. and the
corresponding 2-digit report code used to represent
the restoral-to-normal of the tamper condition
6 3 4 Event Logger ---
Addresses the tamper codes and their restorals given to
Event Logging modules; press [ENTER]
6 3 4 1 Tamper --- press [ENTER] to begin
00 enter the 2-digit report code used to represent a
tamper condition on the Event Logging module
6 3 4 2
Event Logging
Module Tamper
Restore
press [ENTER] to begin
00 enter the 2-digit report code used to represent the
restoral-to-normal of the tamper condition