Installation and Programming Manual
3-68
REPORT CODES: POWER SUPPLY ACCESSORY MODULE TROUBLE
Quick Key Item Default Explanation
6 5
POWER SUPPLY
ACCESSORY
MODULE TROUBLE
---
• used to report the codes generated when the
following series of troubles related to the
operation of the Power Supply Accessory
Module is detected (or restored)
• press [ENTER] to begin
6 5 1
Trouble
Conditions
---
addresses the trouble codes assigned to the
Power Supply Accessory Module;
Press [ENTER]
Low Battery press [ENTER] to begin
6 5 1 1
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent the detection of a
weak (or missing) standby battery wired to the
module
Bell --- press [ENTER] to begin
6 5 1 2
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent a trouble
condition involving the supervision of an external
sounder wired to the module
AC Loss --- press [ENTER] to begin
6 5 1 3
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent a trouble
condition related to the AC Power supplied to the
Pro-24
AUX Fail --- press [ENTER] to begin
6 5 1 4
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent a trouble
condition related to the loss of Auxiliary Power
supplied by the module
INSTALLER PROG:
6)REPORT CODES
↓