EasyManua.ls Logo

Risco Pro-24 - Page 95

Risco Pro-24
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and Programming Manual 3-69
REPORT CODES: POWER SUPPLY ACCESSORY
MODULE TROUBLE RESTORALS
Quick Key Item Default Explanation
POWER SUPPLY
ACCESSORY
MODULE TROUBLE
RESTORALS
---
used to report the codes generated when the
following series of troubles related to the
operation of the Power Supply Accessory Module
is detected (or restored)
press [ENTER] to begin
6 5 2 Trouble Restorals ---
addresses the trouble restoral codes assigned to
the Power Supply Accessory Module;
press [ENTER]
Low Battery --- press [ENTER] to begin
6 5 2 1
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent the restoral-to-
normal of a weak (or missing) standby battery wired
to the module
Bell --- press [ENTER] to begin
6 5 2 2
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent the restoral-to-
normal of a supervisory condition involving an
external sounder wired to the module
AC --- press [ENTER] to begin
6 5 2 3
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent the restoral-to-
normal of the AC Power supplied to the module
AUX --- press [ENTER] to begin
6 5 2 4
00 enter the PS Module’s 1-digit physical I.D. and the 2-
digit report code used to represent the restoral-to-
normal of the Auxiliary Power supplied by the module
INSTALLER PROG:
6)REPORT CODES