3. SETTING FOR COMMUNICATION
IMAE02-E3
6
3.3 Device Address Setting
Set the device address by using numerals from 0 to 99. Press the UP or DOWN key to change the
numeral, and also press the shift key to shift the digit.
Symbol Name Setting range Description
Factory
set value
Device address 0 to 99 Sets the AE500 device address. 0
Add
When the communication parameter was changed, always turn on the power again.
Otherwise, no communication is performed by using the changed value.
If key operation is not performed for more than 1 minute without pressing the SET key after
the device address is set, the AE500 is automatically changed to PV display. In this case, the
set device address returns to the value before the setting is changed.
Setting procedure
Example: When setting device address to 15.
1. Change the AE500 to communication setting mode, and then display the device address
For details, see the 3.1 Transfer to Communication Setting Mode (P. 4) and 3.2
Communication Parameter Selection (P. 5).
Continued on the next page.
SET
ALM4ALM1 ALM2
ALM3
Device address