3. SETTING FOR COMUNICATION
IMAE02-E3
13
3.6 Interval Time Setting
Set the interval time. Press the UP or DOWN key to change the numeral, and press the shift key to
shift the digit.
Symbol Name Setting range Description
Factory
set value
Interval time set
value
0 to 150
*
Sets the value to set the
interval time.
5
InT
* Can be set up to 250 ms if converted to interval time.
Equations for calculating interval time and interval time set value
Equations :
Interval time = Interval time set value
×
1.666 ms
Interval time set value = Interval time
÷
1.666 ms
When the communication parameter was changed, always turn on the power again.
Otherwise, no communication is performed by using the changed value.
If key operation is not performed for more than 1 minute without pressing the SET key after
the device address is set, the AE500 is automatically changed to PV display. In this case, the
set interval time set value returns to the value before the setting is changed.
Setting procedure
Example: When setting interval time to 250 ms.
1. Change the AE500 to communication setting mode, and then display the interval time set value
For details, see the 3.1 Transfer to Communication Setting Mode (P. 4) and 3.2
Communication Parameter Selection (P. 5).
Continued on the next page.
SET
ALM4ALM1 ALM2
ALM3
Interval time