Robertshaw 9610 - Changing Fahrenheit to Celsius; QuickSet Programming Mode

Robertshaw 9610
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Press Press
To change
Temperature Differential*
*T
HE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 1°. THIS MEANS
THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM
THE TEMPERATURE SETTING
, THE SYSTEM WILL TURN ON. IF THE SYSTEM TURNS
ON TOO OFTEN
, INCREASE THE TEMPERATURE DIFFERENTIAL.
4. Press Press
To change
Residual Cooling**
**THE RESIDUAL COOL FEATURE WILL KEEP THE SYSTEM FAN ON FOR AN ADDITIONAL 30, 60 OR 90
SECONDS AFTER THE COMPRESSOR CYCLES OFF. RESIDUAL COOLING CAN ONLY BE PROGRAMMED WHEN
SETTING THE COOLING PROGRAM
.
Changing Fahrenheit (F) to Celsius (C)
Press and Hold SET Press
Release both simultaneously.
QuickSet™ Programming Mode*
1. Place COOL-OFF-HEAT
in HEAT or COOL position.
2. Press & Hold SET. Press the d button.
Release simultaneously.
3. The MORN indicator should be blinking. Program the Time-of-Day and
the temperature as outlined in the Setting Daily Program section.
*QuickSet™ will program all 7 days of the week with the same program.
Individual days can then be changed or modified.
6
SET P
>
>
SET
P
>
>
SET
P
>
PROG
MAN
SET PROG/MAN COOL-OFF-HEAT AUTO - ON
>
>
COOL-OFF-HEAT
110-655B.qxd 11/27/06 4:38 PM Page 6