FILTER Setting: Display SE Fl, ashing 1000 (the default value 1000
hours), select from 50-2000 hours.
Temperature Calibration: Display CAL and ashing 0°F
(the default value 0), select from -3-3°F.
Minimum compressor on time: Display AN ON and ashing OFF
(default setting), select from OFF, 3, 4 or 5 minutes.
Compressor Delay Time Setting: Display CO OF and ashing ON
(default setting), select from ON or OFF.
Cooling Differential Setting: Display df CO and ashing 0.6,
choose from 0.2-2.0 (factory default setting: 0.6°F).
Heating Differential Setting: Display df HE and ashing 0.5,
choose from 0.2-2.0 (factory default setting: 0.5°F).
°F/°C Selection: Setting F (Fahrenheit) or C (Celsius).
24H/12H Selection: Setting the 24 hour or 12 hour time format.
ELEC/GAS Selection: Select the ELEC or GAS.