What to do if Robomow Lawn Mower displays 'Failure: xyz'?
H
Heather Hill PhDAug 31, 2025
If the Robomow Lawn Mower displays 'Failure: xyz', press ‘go’ to confirm the message. If it persists, remove the battery fuse for 10 seconds and retry. If it still appears, contact your service dealer.
S
stephanie83Aug 31, 2025
What to do if Robomow RM510 displays 'Drive overheat cooling, wait…'?
D
Daniel PhillipsAug 31, 2025
If Robomow Lawn Mower displays 'Drive overheat cooling, wait…', it means the drive motors have been working under a severe load for too long. Robomow will automatically renew operation when the motors cool down. If there is a short-circuit detected, contact your service dealer.
S
Sara HughesAug 25, 2025
Why is the ‘Cut wire’ indicator flashing on my Robomow Lawn Mower?
A
Anne GoodmanAug 25, 2025
If the 'Cut wire' indicator is flashing on the Perimeter Switch, or the Base Station beeps continuously, it means the wire is disconnected or cut. Ensure the wire is plugged in and firmly attached to the Perimeter Switch or Base Station. Walk the perimeter to look for cuts or breaks and repair them using Robomow wire splice connectors. Also, check and repair any loose, poor, or corroded connections.
H
hebertamandaAug 30, 2025
What to do if Robomow RM510 displays 'Check signal Press GO'?
J
Jodi ButlerAug 30, 2025
The Robomow Lawn Mower displays 'Check signal Press GO' because there is no fitting between the 'Signal type' setting and the signal jumper, automatic operation is initiated outside the perimeter wire, the perimeter wire is connected with the wrong polarity, or there's signal interference. Set the 'Signal type' menu to 'A' and confirm the jumper is installed, or set it to 'B' and remove the jumper. Place the mower inside the lawn. Change the wires connected to the plot connector. Call service for help in case of signal interference.
D
Dr. Tyler Clark DDSAug 29, 2025
What to do if Robomow RM510 Lawn Mower displays 'Change wires in plot connector'?
M
Margaret ScottAug 29, 2025
The Robomow Lawn Mower displays 'Change wires in plot connector' because the perimeter wire is connected to the plot connector with the wrong polarity. Change the two wires connected to the plot connector (the green connector connected to the Base Station).
A
ashley64Aug 29, 2025
What to do if Robomow Lawn Mower displays 'Bumper pressed'?
M
Michael WhiteAug 29, 2025
The Robomow Lawn Mower displays 'Bumper pressed' because the bumper is constantly being pressed. Move the mower away from the object pressing against the bumper.
R
Ryan WhiteAug 28, 2025
What to do if Robomow Lawn Mower displays 'Base problem'?
V
Victor MayoAug 28, 2025
The Robomow Lawn Mower displays 'Base problem' because it fails to enter the Base Station 3 times. Adjust the Base Station position, clean the contacts, confirm cable connections, and ensure the Base Station is level.
J
James JacksonAug 28, 2025
What to do if Robomow RM510 Lawn Mower displays 'Adjust wire then press GO'?
A
Andrew CarrAug 28, 2025
The Robomow Lawn Mower displays 'Adjust wire then press GO' because it detects an obstacle along the edge in ‘Wire position test’ mode. Adjust the wire where it collides with the obstacle or remove the obstacle, then press ‘GO’ to continue.
S
Sabrina BrownAug 27, 2025
What to do if Robomow RM510 displays 'Low battery'?
U
ubarnesAug 27, 2025
The Robomow Lawn Mower displays 'Low battery' because it's searching for the Base Station with low battery voltage or it skipped the last start time due to low battery. Manually drive or carry the mower to the Base Station for charging. Ensure there's enough time between departures for the battery to charge (min 16 hours).
W
William WilsonAug 27, 2025
What to do if Robomow RM510 Lawn Mower displays 'No wire signal'?
L
lauren86Aug 27, 2025
The Robomow Lawn Mower displays 'No wire signal' because the Base Station/Perimeter Switch is not turned on, not connected to the zone, or the perimeter wire is cut. Ensure the Base Station is connected to the mains supply and disconnect/reconnect it after 10 seconds. Check the Perimeter Switch is connected to the correct zone and is turned on. Inspect the perimeter wire for cuts.