Maintenance
Repair
MagneMover LITE Service Manual 131
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
1. Stop all motion on the path where the precision locator stand z-datums is located.
2. Remove the M4 screws that secure the z-datums to the inner and outer supports as
shown in Figure 53 and remove the z-datums.
3. Clean the z-datum mounting surfaces of the stand with Isopropyl alcohol to remove
any debris.
4. Install the new z-datum using M4 screws and Loctite 243, tighten to 5 in-lbs as shown
in Figure 53.
5. Return the MM LITE transport system to normal operation.