the entire range. Preparations for controlling real expression shutters are already included in
the organ software. Note: Please refer to the “Expression Range” section.
Contact your authorized Rodgers representative for additional information.
PIPES OFF/ANCILLARY ON
If the Rodgers 835 is equipped with pipe ranks, certain stops will control pipe voices and
other stops will control digitally sampled voices. There are two tilt tabs affecting the pipe
stops of all divisions simultaneously (ANCILLARY ON and PIPES OFF).
When the Ancillary tab is engaged, electronic voices play from the pipe stops. When the
Pipes Off tab is engaged, the real wind-blown pipes turn off. Note: If a Pipes Off tab is
engaged, the corresponding Ancillary tab must also be engaged for the stop(s) to sound.
CONSOLE LAMP DIMMER
The illumination of the music rack, lighted drawknobs, lighted tilt tabs, and pedal lamps
is adjusted by performing the following procedure. Note: If the console is equipped with
moving drawknobs, only the music rack and pedal lamps are adjustable.
ADJUSTING THE CONSOLE LAMPS:
1. Press and hold the SET piston.
2. Turn the Select Knob counter clockwise (left) until the Console Display reads:
C O N S O L E L A M P S
12
3. Release SET.
4. Rotate the Alpha Dial to the desired intensity. The range is from 1 to 16.
Note: When the organ is turned off, this setting is saved.
AUTOMATIC SHUTDOWN TIMER
When the organ is on and left unattended, the power automatically turns off after two
hours. Operating any key, stop, or control resets the timer for another two hours.
Playing the organ from a remote MIDI keyboard or sequencer will also reset the timer.