MC16 Operating Manual 09.01.2020
Login Options, Inputs, Outputs, Function keys and Local commands can be defined within Access Point
while Access Terminals and Access Doors can be assigned to Access Point. Access Point based on Login
Options can recognize various method of card reading (single, double long) and link them with various
actions in the system.
Area General
Text box Name – enables to name the point.
Text box LCD Message – enables to specify point’s name which will be used on display.
Parameter Keypad Shortcut – enables to select key which will correspond to the point when interactive
options are applied.
Text box Description – enables to enter custom description for the point.
Tab Authentication
Parameter Default Authentication Policy – specifies default identification method for users at the point
(e.g. card and PIN, Only card, etc.)
Parameter Authentication Policy Schedule – enables assignment of schedule to specify Authentication
Policies for the Access Point in various periods. It requires earlier defining of Authentication Policy type
Schedule.
Parameter Failed Attempts Time [s] – specifies the time when user identification attempts with unknown
Authentication Factor are monitored for the purpose of Access Point blocking.
Parameter Failed Attempts Limit – specifies the number of user identification attempts with unknown
Authentication Factor for the purpose of Access Point blocking.
Parameter Failed Attempts Blocking Time [min] – specifies the time for Access Point blocking when
Failed Attempt Limit is reached within Failed Attempt Time. It is possible to block the point indefinitely and
then the point can be unblocked with [258] input function.
Tab Authorisation Mode
Parameter Default Authorisation Mode – specifies default user authorisation method at Access Point.
Available values:
Normal Authorisation – access is granted after verification of user Authorisations (rights).
Positive Authorisation – access granting does not require user Authorisations (rights).
Negative Authorisation – access is denied regardless of user Authorisations (rights) excluding
Access Credentials with Master exemption.
External Authorisation – regardless of user Authorisations (rights), access is granted when
confirmed by input or function key with the function [185].
Delayed Authorisation – regardless of user Authorisations (rights), access can be blocked by input
or function key with the function [186].
Disabled Authorisation – access is denied regardless of user Authorisations (rights) including
Access Credentials with Master exemption.
Parameter External Authorisation Time – specifies maximal time for activation of the function [185] for
External Authorisation.
Parameter Delayed Authorisation Time – specifies maximal time for activation of the function [186] for
Delayed Authorisation.
Tab Zone Options
Info box Alarm Zone – specifies Alarm Zone to which the Access Point is assigned to.
Info box Entry Point – specifies Access Zone for which the Access Point is Entry Point.
Info box Exit Point – specifies Access Zone for which the Access Point is Exit Point.
Info box Internal Point - specifies Access Zone for which the Access Point is Internal Point.
Option Occupancy Count Enabled – when the option is disabled then occupancy count and anti-passback
are not applied at this Access Point. By default the option is enabled.
Option Lower Limit Enabled – when the option is disabled then access restrictions related to Occupancy
Count Lower Limit are not applied. By default the option is enabled.
Option Upper Limit Enabled – when the option is disabled then access restrictions related to Occupancy
Count Upper Limit are not applied. By default the option is enabled.