MC16 Operating Manual 09.01.2020
Area General
Text box Name – enables to name the door.
Parameter Group – enables to assign door to previously created Access Door Group.
Text box LCD Message – enables to specify door’s name which will be used on display.
Parameter Keypad Shortcut – enables to select key which will correspond to the door when interactive
options are applied.
Text box Description – enables to enter custom description for the door.
Area Door Mode Options
Parameter Default Door Mode – specifies default Door Mode. Available values:
Normal – access can be granted for user with adequate Authorisation(s).
Unlocked – access is granted without user identification. Door lock is permanently released.
Conditional Unlocked – the door is in Normal Mode and when access is granted based on user
Authorisation(s), then it switches to Unlocked Mode.
Locked – access cannot be granted regardless of user Authorisation(s). Door lock is permanently
locked.
Parameter Door Mode Schedule – enables assignment of schedule to specify Door Modes for the Access
Door in various periods. It requires earlier defining of Door Mode type Schedule.
Area Door Options
Parameter Re-lock – specifies if door lock release is shortened after access granting. Available values:
Disabled – parameter disabled.
Clear lock pulse after door opening – the output for door lock control is released after door
opening detection i.e. after signal from input with the function [130] (door contact) and not after time
defined by the parameter Lock Pulse or Lock Pulse Extended.
Clear lock pulse after door closing – the output for door lock control is released after door closing
detection i.e. after signal from input with the function [130] (door contact) and not after time defined
by the parameter Lock Pulse or Lock Pulse Extended.
Parameter Lock Pulse [s] – specifies default door lock release time when access is granted based on input
functions [128], [151] or [175].
Parameter Lock Pulse Extended [s] – specifies default door lock release time when access is granted
based on input functions [129], [152] or [176].
Parameter Lock Pulse Delay [s] – specifies delay for door lock release when access is granted.
Parameter Door Open Too Long Time [s] – specifies maximal time to shut the door. When elapsed then
Door Open Too Long Alarm is raised.
Option Cancel Door Open Too Long Alarm when door closed – when the option is enabled then door
closing cancels Door Open Too Long Alarm.
Option Door Open Too Long Alarm not only in Normal Door Mode – when the option is enabled then
Door Open Too Long Alarm can be raised also for other than Normal Door Modes.
Parameter Door Open Too Long Prealarm Time [s] – specifies when the prealarm (output with function
[030]) is activated to warn that Door Open Too Long Alarm will be raised soon. The parameter defines how
many seconds before the alarm, the warning (prealarm) is started.
Option Disable event [321]: Door Forced Alarm – when the option is enabled then event [321] is not
generated for the Access Door.
Tab Inputs
The tab is available when an Access Door is created and it enables to assign Input(s) to the door. Input
parameters and functions are listed within the description of Input objects.
Tab Outputs
The tab is available when an Access Door is created and it enables to assign Output(s) to the door. Output
parameters and functions are listed within the description of Output objects.
Tab Function Keys
The tab is available when an Access Door is created and it enables to assign Function Key(s) to the door.
Function key parameters and functions are listed within the description of Function key objects.