MC16 Operating Manual 09.01.2020
When triggered then Cafeteria flag and output with function [215] are
switched off while outputs with functions [213] and [214] are switched on. The
function is available only for MC16-HRC controllers.
Set Alternately Cafeteria Flag
ON/OFF
When triggered then Cafeteria flag is switched to opposite state. Outputs with
functions [212], [213], [214] and [215] are switched accordingly. The function
is available only for MC16-HRC controllers.
Set Luggage Service Flag ON
When triggered then Cafeteria flag and outputs with functions [216], [218] and
[219] are switched on. The function is available only for MC16-HRC
controllers.
Set Luggage Service Flag OFF
When triggered then Luggage Service flag and output with function [219] are
switched off while outputs with functions [217] and [218] are switched on. The
function is available only for MC16-HRC controllers.
Set Alternately Luggage Service
Flag ON/OFF
When triggered then Luggage Service flag is switched to opposite state.
Outputs with functions [216], [217], [218] and [219] are switched accordingly.
The function is available only for MC16-HRC controllers.
When triggered then intruder alarm is raised according to Alarm Zone
settings in Alarm Functions area. The line can be used for connection of
alarm detector.
Delayed Intruder Detection
When triggered then delayed intruder alarm is raised according to Alarm
Zone settings in Alarm Functions area. The line can be used for connection of
alarm detector.
When triggered then identification at Access Point is disabled for all users
including Access Credentials with Master exemption.
When triggered then Access Point is enabled if previously disabled with the
function [257] or as a result of failed authentication attempts.
Disable Access Point Toggle
As long as triggered then access granting at Access Point is disabled for all
users including Access Credentials with Master exemption.