MC16 Operating Manual 09.01.2020
27/52
controllers.
207
Set Cafeteria Flag OFF
Event
Access Point
When triggered then Cafeteria flag and output with function [215] are
switched off while outputs with functions [213] and [214] are switched on. The
function is available only for MC16-HRC controllers.
208
Set Alternately Cafeteria Flag
ON/OFF
Event
Access Point
When triggered then Cafeteria flag is switched to opposite state. Outputs with
functions [212], [213], [214] and [215] are switched accordingly. The function
is available only for MC16-HRC controllers.
209
Set Luggage Service Flag ON
Event
Access Point
When triggered then Cafeteria flag and outputs with functions [216], [218] and
[219] are switched on. The function is available only for MC16-HRC
controllers.
210
Set Luggage Service Flag OFF
Event
Access Point
When triggered then Luggage Service flag and output with function [219] are
switched off while outputs with functions [217] and [218] are switched on. The
function is available only for MC16-HRC controllers.
211
Set Alternately Luggage Service
Flag ON/OFF
Event
Access Point
When triggered then Luggage Service flag is switched to opposite state.
Outputs with functions [216], [217], [218] and [219] are switched accordingly.
The function is available only for MC16-HRC controllers.
220
Intruder Detection
Event
Alarm Zone
When triggered then intruder alarm is raised according to Alarm Zone
settings in Alarm Functions area. The line can be used for connection of
alarm detector.
221
Delayed Intruder Detection
Event
Alarm Zone
When triggered then delayed intruder alarm is raised according to Alarm
Zone settings in Alarm Functions area. The line can be used for connection of
alarm detector.
257
Disable Access Point
Event
Access Point
When triggered then identification at Access Point is disabled for all users
including Access Credentials with Master exemption.
258
Enable Access Point
Event
Access Point
When triggered then Access Point is enabled if previously disabled with the
function [257] or as a result of failed authentication attempts.
259
Disable Access Point Toggle
Toggle
Access Point
As long as triggered then access granting at Access Point is disabled for all
users including Access Credentials with Master exemption.

Other manuals for Roger MC16