PR301v2.1UK.doc 02-07-29
7
[7] – D
ELETES ALL
NORMAL
AND
SWITCHER
USERS
[7]
+ [#] + [7] + [#]
Note: The MASTER and INSTALLER identifiers remain.
[8] – E
NTRY TO THE
I
NSTALLER
P
ROGRAMMING
M
ODE
Note: After EEPROM memory RESET the MASTER and also performs the function of the INSTALLER identifier (MASTER =
INSTALLER).
[8
] + [INSTALLER code] + [#] or [8] + [INSTALLER card]
If [Reprogramming disable] option is on, this function does not work, in order to remove this option EEPROM RESET must be done.
[0] – E
XIT FROM
I
NSTALLER
P
ROGRAMMING MODE
[0]
+ [#]
After an exit from the programming mode, the reader performs the RESTART operation and enters the CLOSED condition.