EasyManua.ls Logo

Rohde & Schwarz RTA4004 - Switching

Rohde & Schwarz RTA4004
861 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTA4000
761User Manual 1335.7898.02 ─ 08
17.12.16 Switching
POWer:SWITching:EXECute........................................................................................... 761
POWer:SWITching:GATE:CONDuction:STARt...................................................................761
POWer:SWITching:GATE:CONDuction:STOP...................................................................761
POWer:SWITching:GATE:NCONduction:STARt.................................................................762
POWer:SWITching:GATE:NCONduction:STOP................................................................. 762
POWer:SWITching:GATE:SWAVe.................................................................................... 762
POWer:SWITching:GATE:TOFF:STARt............................................................................ 762
POWer:SWITching:GATE:TOFF:STOP.............................................................................762
POWer:SWITching:GATE:TON:STARt..............................................................................762
POWer:SWITching:GATE:TON:STOP.............................................................................. 762
POWer:SWITching:REPort:ADD...................................................................................... 763
POWer:SWITching:RESult:CONDuction:ENERgy?............................................................ 763
POWer:SWITching:RESult:CONDuction:POWer?..............................................................763
POWer:SWITching:RESult:NCONduction:ENERgy?.......................................................... 763
POWer:SWITching:RESult:NCONduction:POWer?............................................................ 763
POWer:SWITching:RESult:TOFF:ENERgy?......................................................................763
POWer:SWITching:RESult:TOFF:POWer?........................................................................764
POWer:SWITching:RESult:TON:ENERgy?........................................................................764
POWer:SWITching:RESult:TON:POWer?......................................................................... 764
POWer:SWITching:RESult:TOTal:ENERgy?......................................................................764
POWer:SWITching:RESult:TOTal:POWer?........................................................................764
POWer:SWITching:TYPE................................................................................................764
POWer:SWITching:EXECute
Starts the switching loss measurement.
Usage:
Event
POWer:SWITching:GATE:CONDuction:STARt <StartTime>
Sets the start time for the conduction gate. This value is simultaneously the stop time
for the turn on gate.
Parameters:
<StartTime>
POWer:SWITching:GATE:CONDuction:STOP <StopTime>
Sets the stop time for the conduction gate. This value is simultaneously the start time
for the turn off gate.
Parameters:
<StopTime>
Power analysis (option R&S RTA-K31)

Table of Contents

Other manuals for Rohde & Schwarz RTA4004

Related product manuals