EasyManua.ls Logo

Roland Fantom G8

Roland Fantom G8
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
270
Editing a Sample
This operation raises the level of the entire sample as much as
possible without exceeding the maximum level. In some cases, the
volume of a phrase you resampled (p. 260) will be lower than the
volume of the original phrase. In this case, it is a good idea to boost
the volume by executing the Normalize operation.
1.
Press [SAMPLE] to access the Sample Edit screen.
2.
Press [F3 (Modify)].
The Sample Modify Menu window will appear.
3.
Press
or to select “Normalize,” and then press [F8
(Select)].
To cancel, press [F7 (Cancel)].
4.
If you want to replace the current sample with the
normalized sample, press [F6 (Over Write)].
5.
Press [F8 (Execute)].
A message will ask you for confirmation.
6.
Press [F7 (OK)] to execute.
To cancel, press [F8 (EXIT)].
If [F6 (Over Write)] is off,
pressing [F7 (OK)] to execute
will
create the edited sample in the lowest unused sample number
in the list.
This operation applies an envelope (time-variant change) to the
volume of the sample. You can also adjust the volume of the entire
sample.
1.
Press [SAMPLE] to access the Sample Edit screen.
2.
Press [F3 (Modify)].
The Sample Modify Menu window will appear.
3.
Press
or to select “Amp,” and then press [F8
(Select)].
To cancel, press [F7 (Cancel)].
4.
Use VALUE dial or [INC] [DEC] to set the value.
Rate:
Specifies the rate of volume boost.
This specifies how much boost will be applied relative to the
current volume. The entire sample you select will be boosted.
Value:
0–400%
5.
If you want to specify a point, press [F5 (Point)] to light it
into red. Press
or to select a parameter, and then
use VALUE dial or [INC] [DEC] to set the value.
Current Point:
Specifies the currently selected point. Beginning
near the start point, the points will be numbered 1, 2, 3, or 4.
Value:
1–4
Point 1–4:
Location of the current point
Rate 1–4:
Amplification ratio of the current point
Specifies how the volume of each point is to be boosted relative
to the current value.
Value:
0–400%
6.
If you want to replace the current sample with the
normalized sample, press [F6 (Over Write)].
7.
Press [F8 (Execute)].
A message will ask you for confirmation.
8.
Press [F7 (OK)] to execute.
To cancel, press [F8 (EXIT)].
If [F6 (Over Write)] is off,
pressing [F7 (OK)] to execute
will
create the edited sample in the lowest unused sample number
in the list.
Maximizing the Volume of a
Sample (Normalize)
Amp
Fantom-G_r_e.book 270 ページ 2009年7月2日 木曜日 午後2時55分

Table of Contents

Other manuals for Roland Fantom G8

Related product manuals