Mar. 2010 SPD-30
1. Version Display [1/15 VERSION]
fig.test1.eps_80
1. Verify the version.
2. Press [Button 3] to advance to the next item.
2. MIDI Test [2/15 MIDI]
fig.test2.eps_80
1. Connect the MIDI IN and MIDI OUT connectors using the MIDI cable.
When the connection is detected, the message Connect!! appears.
2. Disconnect the MIDI cable.
When the severed connection is detected, the messages Disconnect,
Complete, and OK!! are displayed, and execution automatically
advances to the next item.
3. SW (Switch) and LED Test
[3/15 SW/LED]
1. Verify that all LEDs are dark.
2. Press, in sequence, all buttons other than [POWER], and verify that the
corresponding on-screen - changes to o and the LED of the pressed
button lights up.
Successively pressing [QUICK] makes the LEDs light up in this sequence:
PAD1 -> PAD2 -> ... -> PAD8 -> PHRASE LOOP (9 locations in all).
The LED color is green for [PLAY], blue for [V-LINK], and red for others.
If switch or LED operation is abnormal, X is displayed.
fig.test3.eps_80
When all buttons have been tested, NEXT appears at the bottom right of
the screen.
3. Press [Button 3] to advance to the next item.
4. Encoder Test [4/15 ENCODER]
fig.test4.eps_80
1. Turn [Knob 3] clockwise a little at a time.
2. Verify that the value of ENC3 on the right side of the screen increases and
the screen contrast simultaneously becomes progressively darker.
When the number reaches 24, OK is displayed above and to the right of
ENC3.
3. Turn [Knob 3] counterclockwise a little at a time.
4. Verify that the value of ENC3 on the right side of the screen decreases
and the screen contrast becomes progressively lighter.
When the number reaches -24, OK is displayed below and to the left of
ENC3.
5. Turn [Knob 3] to adjust the value of ENC3 to 0.
6. Test [Knob 2] and [Knob 1] in the same way.
* Note, however, that the contrast does not change.
When all operation of [Knob 3], [Knob 2], and [Knob 1] has been verified,
execution automatically advances to the next item.