RCP-ME User Guide (v4.0) Protects and Locks • 63
3. In the Configuration section, select the Panel Locked check box.
4. Send the current configuration file to the device (see “To send the current configuration to a panel” on
page 74).
The RCP-ME is locked.
If a panel LOCK button is assigned, it can be pressed to unlock the RCP-ME.
To lock the RCP-ME using a panel lock button
Press the panel LOCK button.
The panel
LOCK button illuminates. A brief KEY LOCK message is shown on the screen.
Every button on the RCP-ME becomes inactive except for the panel
LOCK button.
To unlock the RCP-ME using a panel lock button
If you want to unlock the RCP-ME, press the panel LOCK button.
The panel
LOCK button switches off. A brief KEY UNLOCK message is shown on the screen.
To lock the RCP-ME using a protect button
Hold the PROTECT button for 3 seconds.
A brief KEY LOCK message is shown on the screen.
If a panel
LOCK button is assigned to the RCP-ME, this button illuminates.
Every button on the RCP-ME becomes inactive, except for the
PROTECT button and panel LOCK button, if
assigned.
To unlock the RCP-ME when locked by a protect button
If the RCP-ME is locked using a protect button and you want to unlock it, hold the protect button or press the
panel lock button, if assigned.
A brief KEY UNLOCK message is shown on the screen.
The PROTECT button does not illuminate.
Protecting a Destination
You can use a protect button to prevent switching of critical crosspoints by others. The protect function ensures that
the selected destination can only receive the selected source across the selected levels. Once protected, the selected
levels on a destination cannot be switched by other remote control panels (or by the same remote control panel if
Block All Panels is selected). The source is not protected and can be freely routed to other destinations if required.
You can protect any number of destinations.
You can set the extent of protection that is used via DashBoard, such as protected against other remote control
panels or protected against all remote control panels (see “Locking an RCP-ME” on page 62).
To protect a destination
1. Make the switch.
2. Press the
PROTECT button.
The
PROTECT button and the protected crosspoint are illuminated. The screen indicates that a protect is in
place by showing the protection indicator at the bottom left of the screen.
Figure 10.1 Protected Crosspoint and Protection Indicator
1234
SRC: Server 2
DST: Monitor
L