AC-015 Page 21 March 2008
Events and Event Actions
Tamper Event
A tamper event will cause AC-015 tamper output to
open and alarm sound generated if enabled. A
tamper event may occur due to several reasons:
AC-015 cover is removed or broken.
A reader sensor wire is being disconnected from
the AC-015 reader input terminal.
A tamper data signal is received from one of
the reader sensors.
Clearing Tamper Events
To clear a tamper event enter a valid employee or
Lock Strike code that will open the door locker output
at that instance. For example, during Secured status,
entering Lock Strike Code 1 from the external reader
will not clear tamper because it’s not permitted to
open the door at this status. However, applying the
same code from the internal reader will clear tamper
output.