AC-225 Panel Set-Up
3.5 Reader
Proximity & keypad readers are supplied with a limited cable.
The color of the cable cover represents the cable’s function.
Note:
When extending the cable distance, be careful with the
color of the cable cover.
Refer to the reader specifications for the maximum cable
length (typically 150m with an 18 AWG cable).
Figure 7: Reader Wiring
3.6 MD-IO84
The MD-IO84 is an optional I/O expansion board which adds
four relay outputs and eight supervised inputs to an Access
Control Panel. Attach the MD-IO84 to the AC-225's expansion
slot. For more information, see the MD-IO84 Installation and
User Guide.