Controller Operation
32 AYC-Ex5/T65 Series Installation and Programming Manual
programmed for Fail Secure Operation, the door is locked until
is
pressed. When the Lock Strike is programmed for Fail Safe
Operation, the door is constantly unlocked.
4.2.3 Secure Mode
The left LED is red.
Only Secure and Master users can access the premises in Secured
mode.
A Secure user must enter the Primary and Secondary codes to gain
entry. After entering the Primary code, the right LED flashes green
for 10 seconds, during which the Secondary code must be entered.
A Master user only needs to present the code once to gain entry.
4.2.4 Changing the Modes of Operation
4.2.4.1 Changing from Normal Mode to Secure Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Normal to Secure mode:
1. Enter the Normal/Secure code.
The left LED flashes red.
2. Press # to confirm the mode change.
The left LED stops flashing.
4.2.4.2 Changing from Secure Mode to Normal Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Secure to Normal mode:
1. Enter the Normal/Secure code.
Green
Red

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-E 5 Series and is the answer not in the manual?

Rosslare AYC-E 5 Series Specifications

General IconGeneral
BrandRosslare
ModelAYC-E 5 Series
CategoryController
LanguageEnglish

Related product manuals