60
Column Greasing:
Two post lifts finished with powder coat must have grease applied to the columns. Columns need to be re-greased every
5000 cycles or six months, whichever comes sooner. If your lift has a model number that matches the following table,
grease the columns with either Lighting grease, Tuf Oil, Sil Glide, or an equivalent grease.
Apply the grease to the columns by wiping on a thin layer and polishing with a rag. Only apply grease on surfaces of the
columns where the slider blocks make contact. Be careful not to apply too much grease, only a thin layer is needed, wipe
off excess.
Lift Series Model Number
SPOA7
1000 SPOA7x10xx
1100 SPOA7x11xx
1200 SPOA7x12xx
SPO10
1000 SPO10x10xx
1100 SPO10x11xx
1200 SPO10x12xx
SPOA10
1000 SPOA10x10xx
1100 SPOA10x11xx
1200 SPOA10x12xx
If you are not completely familiar with automotive lift
maintenance procedures; STOP: Contact factory for
instructions. To avoid personal injury, permit only qualified
personnel to perform maintenance on this equipment.
• Always keep bolts tight. Check periodically.
• Always keep lift components clean.
• Always if oil leakage is observed, call local service
representative.
• Always if electrical problems develop, call local service
representative.
• Daily: Check cables and sheaves for wear. Observe for frayed
cable strands. Wipe cables with a rag to detect hard to see
small broken cable strands. Replace cables showing any
broken strands. Replace worn parts as required with genuine
Rotary parts.
• Daily: Inspect adapters for damage or excessive wear.
Replace as required with genuine Rotary parts.
• Monthly: Check equalizer cable tension. Adjust per lift
installation instructions. If there are no more threads available
for adjustment, replace the cable. Do not use washers to
stand off the nut to use previously used threads.
• Monthly: Lubricate arm pins with lubricating oil unless
lubricating with grease or anti-seize on a semi-annual basis.
• Monthly: Lubricate locking latch shafts. Push latch handle
several times for oil to penetrate pivot points.
• Every 3 Months: Check anchor bolts for tightness. Anchors
should be torqued to 65 ft/lbs (88 Nm).
• Semi-Annually: Check fluid level of lift power unit and refill if
required per lift installation instructions.
• Replace all caution, warning or safety related decals on the lift
if unable to read or missing. Reorder labels from Rotary Lift.
MAINTENANCE INSTRUCTIONS