A4 US
US
A4
US
A4
A4 US
13
Redefining Flow Control
End user advice on disposal at end of life of the product
Subject Definition Remarks / examples Hazardous Recyclable EU Waste Code Disposal
Electrical & Electronic
Equipment
Printed circuit boards
Wire
All Products
All Products
Yes
Yes
Yes
Yes
20 01 35
17 04 10
Use specialist recyclers
Glass Lens/Window IQ No Yes 16 01 20 Use specialist recyclers
Metals
Aluminium
Copper/Brass
Covers
Wire
No
No
Yes
Yes
17 04 02
17 04 01
Use licensed recyclers
Rubber Seals & O-rings Cover Yes No 16 01 99
May require special treatment before
disposal, use specialist waste disposal
companies
In all cases check local authority regulation before disposal.
9 - Environmental
Maximum Constructional Flamepath Gaps
Flamepath
Max. Gap
(mm)
Min. Length
(mm)
Equipment Type
Electrical Cover / Back Housing
0.15 26.00 All Types and Sizes
Terminal Cover / Back Housing
ATEX / IECEx
0.15 12.50 RHS
Terminal Cover / Back Housing for FM & CSA
0.115 12.50 RHS
Transfer Loom Bush for FM & CSA
0.115 25.00 RHS
Transfer Loom Bush Flamepath
0.15 25.00 RHS