(1) Output voltage ranges 0 to rating voltage continuously adjustable.
(2) Voltage regulation
line regulation ∗0.01%+3mV.
load regulation ∗0.01%+3mV (rating current ∗3A).
load regulation ∗0.01%+5mV (rating current >3A).
(3) Recovery time ∗100µs (50% Load change, minimum load 0.5A).
(4) Ripple & Noise ∗0.5mVrms (5Hz~1MHz) (rating current ∗3A).
Ripple & Noise ∗1.0mVrms (5Hz~1MHz) (rating current >3A).
(5) Temperature coefficient ∗300ppm/ºC.
2-3 Constant Current Operation
(1) Output current range 0 to rating current continuously adjustable.
(2) Current regulation
line regulation ∗0.2%+3mA.
load regulation ∗0.2%+3mA.
(3) Ripple & Noise∗3mArms.
2-4 Indicator Meter
Analog
Meter : Voltmeter and Ammeter each one
Class : 2.5.
Dimensions : 50×50 m/m.
2-5 Insulation
Between chassis and output terminal : 20MO or above (DC500V).
Between chassis and AC cord : 30MO or above (DC500V).