EP Series User Manual
55
switch
Origin: Negative limit switch
Positive homing
Deceleration point: Mechanical
limit position
Origin: Mechanical limit position
Note: This mode is only
available for EPT60.
Negative homing
Deceleration point: Mechanical
limit position
Origin: Mechanical limit position
Note: This mode is only
available for EPT60.
High-speed search origin signal, unit: rpm
Low-speed search origin signal, unit: rpm
Acceleration and deceleration of search origin
signal, unit: r/s^2
Set the machine origin offset, unit: Command
pulse
Note: When the value of parameter P293/294
is positive, it means forward running
Mechanical origin offset and limit processing
method:
Mechanical origin offset and limit
processing method
P293/P294 is the coordinate after
encountering the origin. After
encountering the limit sensor and
re-triggering the origin return, the
origin is reversely searched.
Remark:
Mechanical origin: The mechanical
origin does not coincide with the
mechanical zero point. After finding
the origin switch signal, the current
position parameter P8/9 is forced to
be the set value of the parameter
P293/294.