EasyManua.ls Logo

Ruby Tech ES-2310C - Page 181

Ruby Tech ES-2310C
255 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ES-2310C User Manual
Publication date: Aug., 2010
Revision A5
171
autologout
autologout
Syntax:
autologout <time>
Description:
To set up the timer of autologout.
Argument:
<time>: range 1 to 3600 seconds, 0 for autologout off, current setting is 180
seconds.
Possible value:
< time >: 0,1-3600
Example:
ES-2310C# autologout 3600
Set autologout time to 3600 seconds
bandwidth
set egress-rate
Syntax:
set egress-rate <range> <data_rate>
Description:
To set up the egress-rate of the ports.
Argument:
<range>:syntax 1,5-7, available from 1 to 10
<data_rate>: 66-1024000(Kb).
port 1-8: 66-102400(Kb); port 9-10: 66-1024000(Kb)
Possible value:
<range>: 1 to 10
<data_rate>: 66-102400(Kb) for port 1-8; 66-1024000(Kb) for port 9-10
Example:
ES-2310C(bandwidth)# set egress-rate 1-6 299
set ingress-rate
Syntax:
set ingress-rate <range> <data_rate>
Description:
To set up the ingress-rate of the ports.
Argument:
<range>:syntax 1,5-7, available from 1 to 10
<data_rate>: 66-1024000(Kb).
port 1-8: 66-102400(Kb); port 9-10: 66-1024000(Kb)
Possible value:
<range>: 1 to 10
<data_rate>: 66-102400(Kb) for port 1-8; 66-1024000(Kb) for port 9-10
Example:
ES-2310C(bandwidth)# set ingress-rate 1-6 100

Table of Contents