172
set storm-rate
Syntax:
set storm-rate <range> <data_rate>
Description:
To set up the storm-rate of the ports.
Argument:
<range>:syntax: 1,3-5, available from 1 to 5
1: Disable 2: Broadcast Storm Control
3: Multicast Storm Control
4: Unknown Unicast Storm Control
5: Broadcast, Multicast, Unknown Unicast Storm Control
<data_rate>: 1-100. The value must be the integer.
The value 100 disables broadcast storm control.
Possible value:
<range>: 1 to 5
<data_rate>: 1-100.
Example:
ES-2310C(bandwidth)# set storm-rate 2 99
show
Syntax:
show
Description:
To display all current settings of the bandwidth.
Argument:
None
Possible value:
None
Example:
ES-2310C(bandwidth)# show
Port Ingress Rate(Kb) Egress Rate(Kb)
====== ================== =================
1 102400 102400
2 102400 102400
3 102400 102400
:
:
7 102400 102400
8 102400 102400
9 1024000 1024000
10 1024000 1024000
Broadcast Storm Control
========================================================
Type: Disable
Rate: 100 %