RDLC320 Controller User Manual
40 / 45
© 2016 Ruida Technology. All Rights Reserved.
user.
Delay after Feeding: set the time: 0~9.9s. It is facilitated the feeding device delay debouncing
after moving to the correct position, and waiting for the 2
nd
work when the feeding axis stands still
completely.
Focus Depth Setting: it means the distance from the lens focal point of laser head to Z-axis
original point. If there is no automatic focusing function, this parameter is invalid.
Backlash X: The backlash of X-axis, set the value according to the actual machine, accurate to 1
um, if this value is not 0, the control system will make compensation for backlash.
Backlash Y: The backlash of Y-axis, set the value according to the actual machine, accurate to 1
um, if this value is not 0, the control system will make compensation for backlash.