MODEL 53515/53615/63515/63615/73515/73615
11
Install the system in the place where with the minimum loss in case of
water leakage.
C. Pipeline installation (Take 63615 as example)
Install control valve
a. As the Figure 1-1 shows, select
the riser pipe with 50mm OD, glue
the riser pipe to the bottom strainer
and put it into the mineral tank, cut
off the exceeding pipe out of tank
top opening and make external
rounding.
b. Fill the resin to the tank, and the
height is accordance with the design
code.
c. Install the top strainer to the
valve.
d. Insert the riser tube into control
valve and screw tight control valve.
Note:
The length of riser pipe should be neither 2mm higher nor 5mm
lower than tank top opening, and its top end should be rounded to
avoid damage of O-ring inside the valve.
Avoid filling floccules substance together with resin to the mineral
tank.
Avoid O-ring inside control valve fall out while rotating it on the
tank.
Install flow meter
As Figure1-2 shows, put the sealing ring into nut of flow meter,
screw in water outlet; insert the sensor into flow meter.