When the control valve enters into the regeneration status, all program
can be finished automatically according to the setting time; if you want
one of steps to be terminated early, you can press .
If water inflows too fast, the media in tank will be damaged. When
water inflows slowly, there is a sound of air emptying from drain pipeline.
After changing resin, please empty air in the resin according to the
above Step C.
In the process of trial running, please check the water situation in all
positions, and ensure there is no resin leakage.
The time for Backwash, Brine Draw, Slow Rinse, Fast Rinse and Brine
Refill status can be set and executed according to the calculation in the
formula or suggested from the control valve suppliers.
3.7. Trouble-Shooting
A. Control Valve Fault
Problem
Cause
Correction
1. Softener
fails to
regenerate.
A. Electrical service to unit
has been interrupted.
B. Regeneration cycles set
incorrect.
C. Controller is defective.
D. Motor fails to work.
A. Assure permanent electrical
service (Check fuse, plug, pull
chain or switch).
B. Reset regeneration cycles.
C. Check or replace controller.
D. Check or replace motor.
2.
Regeneration
time is not
correct.
A. Time of day does not set
correctly.
B. Power failure more than
3 days, the time of day
does not reset, is not
correct.
Check program and reset time of
day.