Page #22 background imageLoading...
Page #22 background image
MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
18
Service Days
1-03D
099 Days
Only for Time Clock Type,
regeneration by days.
Service Hours
1-20H
099
Hours
Only for Time Clock Type,
regeneration by hours.
Regeneration
Time
02:00
02:00
00:00
23:59
Regeneration time light on.
Interval
Backwash
Times
F-00
00
020
Interval backwash times. For
example, F-01:indicate service 2
times, backwash 1 time.only for
F68A3,F68C3
Resin Volume
20L
20L
5500L
Resin volume in brine tank (L)
Feed Water
Hardness
Yd1.2
1.2
0.19.9
Feed water hardness (mmol/L)
Exchange
Factor
AL.65
0.65
0.300.99
Relate to the raw water
hardness. When hardness is
higher, the factor is smaller.
Water Treatment
Capacity
10m
3
099.99
m
3
Water treatment capacity in one
circle (m
3
)
Backwash
Time
10min.
09959
Backwash time(Minute)
Brine & Slow
Rinse Time
60min.
09959
Brine & Slow rinse time(Minute)
Brine Refill
Time
5min.
09959
Brine refill time(Minute)
Fast Rinse
Time
10min.
09959
Fast rinse time(Minute)
Maximum
Interval
Regeneration
Days
H-30
30
040
Regenerate on the day even
through the available volume of
treated water do not drop to zero
(0).