EasyManua.ls Logo

Runxin F63C1 - Page 22

Default Icon
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
18
Service Days
1-03D
099 Days
Only for Time Clock Type,
regeneration by days.
Service Hours
1-20H
099
Hours
Only for Time Clock Type,
regeneration by hours.
Regeneration
Time
02:00
02:00
00:00
23:59
Regeneration time light on.
Interval
Backwash
Times
F-00
00
020
Interval backwash times. For
example, F-01:indicate service 2
times, backwash 1 time.only for
F68A3,F68C3
Resin Volume
20L
20L
5500L
Resin volume in brine tank (L)
Feed Water
Hardness
Yd1.2
1.2
0.19.9
Feed water hardness (mmol/L)
Exchange
Factor
AL.65
0.65
0.300.99
Relate to the raw water
hardness. When hardness is
higher, the factor is smaller.
Water Treatment
Capacity
10m
3
099.99
m
3
Water treatment capacity in one
circle (m
3
)
Backwash
Time
10min.
09959
Backwash time(Minute)
Brine & Slow
Rinse Time
60min.
09959
Brine & Slow rinse time(Minute)
Brine Refill
Time
5min.
09959
Brine refill time(Minute)
Fast Rinse
Time
10min.
09959
Fast rinse time(Minute)
Maximum
Interval
Regeneration
Days
H-30
30
040
Regenerate on the day even
through the available volume of
treated water do not drop to zero
(0).

Table of Contents

Related product manuals