MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
17
2.2. Basic Setting & Usage
A. Parameter specifications
Function
Indicat
or
Factory
Default
Parameter
set range
Instruction
Time of Day
Rando
m
00:00
23:59
Set the time of day when use
flash.
Control Mode
A-01
A-01
A-01
Regenerate on the day although
the available volume of treated
water drops to zero (0).
Regeneration starts at the
regeneration time.
A-02
Regenerate immediately when the
available volume of treated water
drops to zero(0).
A-03
Meter Delayed Regeneration type,
but by setting Resin Volume, Feed
Water Hardness, Regeneration
Factor, the controller will calculate
the System Capacity.
Regeneration mode same as
A-01.
A-04
Meter Immediately Regeneration
Type, but by setting Resin Volume,
Feed Water Hardness,
Regeneration Factor, the
controller will calculate the System
Capacity. Regeneration mode
same as A-02.
Unit Mode
HU-01
HU-01
01,02,03
01-m302-gal03-L