MODEL: N74A1-63510/N74A3-63610/N74B1-63510B/N74B3-63610B
28
3.4.Parameter settlement
Service timeT1
Water treatment capacity
Q=V
R
×K÷Y
D
m
3
Hardness of Inlet Water (mmol/L)
Exchange factor (mmol/L) 400~1000.
Down-flow regeneration, take 400~750.
Up-flow regeneration, take 450~1000.
If the inlet water hardness is higher, the
factor is smaller.
Resin volume (m
3
)
By hours: T1=Q÷Q
h
Hour
Water treatment capacity per hour (m
3
/h)
Water treatment capacitym
3
By days T1=Q÷Q
d
Day
Water treatment capacity per day (m
3
/d)
Water treatment capacity (m
3
)
Backwash time T2
It is subject to the turbidity of inlet water. Generally, It is suggested to
be set 1015 minutes. The higher the turbidity is, the longer backwash
time can be set. However, if the turbidity is more than 5 FTU, it should be
better to install a filter in front of the exchanger.
Brine & Slow rinse time T3
T3=(4050)×H
R
min.
Generally, T3=45H
R
min.
In this formula, H
R
——the height of resin in exchange tank (m.)
Brine refill time T4
Down-flow regenerationT40.45×V
R
÷Brine refill speed (min.)
Up-flow regenerationT40.34×V
R
÷Brine refill speed (min.)
In this formula, V
R
—— Resin volume (m
3
)
The Brine refill speed is related to inlet water pressure. It is suggested
to lengthen 1~2 minutes of calculated brine refilling time to make sure there
is enough water in tank. The condition is that there is a level controller
installed in the brine tank
Fast rinse time T5
T5=12×H
R
min.
Generally, the water for fast rinse is 3~6 times of resin volume. It is
suggested to be set 10~16 minutes, but subject to the outlet water reaching