Service Mode :
Starting the service test
Picture 1
Picture 2
A
fter finalizing the above processes; the service program starts automaticly.
Program algrorithm steps follow each other automatically. In case of a problem; the program stops on
the problem step and show failure code. You can understand the problem by looking the failure code.
STEP PROCESS TIME CONTROL
0 Show the last failure
occured before
~6 sec At the beginning of service program
1 Drain ~4 sec Drain pump is running
2 Fill (~3,5lt) ~1min 25
sec
Water inlet valve and flowmeter is controlled.
(At 2,5lt circulation pump starts to run)
3 wash ~1min 10
sec
Circulation pump – detergant dispenser
4 Wash + Heating ~5 min Heater Casing (pressure switch)- NTC- diverter positions
5 Regeneration ~1 min Regeneration value
6 Drain ~20 sec Drain Pump
7 End led highlight
4- Move the programme
selector knob to the reset
position Keep the start/pause
button pressed until program
monitor lights are on and off.
1-Move the programme
selector knob to the first
program and press the
start/pause button while
your machine is not in
operation
2-Keep the start/pause button
pressed down meanwhile
energise the machine by
pressing the On/Off button
3-Keep start/pause button
pressed until flow indicators
are on and off
Start/pause
button
button
Flow
Indicator