REPAIR TECHNIQUES
COMPONENTS AND RESISTANCE VALUES
COMPONENTS
REAL VALUES NOTES
ON / OFF BUTTON
0 Ω ON COMPONENT
ON/OFF BUTTON IS PRESSED
DOOR SWITCH (KAPI KİLİDİ)
CN2.9 – CN2.2 0 Ω
DOOR IS CLOSE
PRESSURE SWITCH
CN2.10 – CN2.2 0 Ω
∞ Ω
FULL FILL WATER
NO WATER
DRAIN PUMP
CN2.2 – CN2.4 143 Ω % ± 7
WATER INLET VALVE
CN2.6 – CN 2.9 3750 Ω ± %10 (20Cº)
REGENERATION VALVE
CN2.10 – CN2.7 4130 Ω ± %10(25 Cº)
SALT SENSOR
CN5.1 – CN5.2 0 Ω WITHOUT SALT
∞ Ω WITH SALT
MEASURE JUST ON THE ELECTRONIC
CARD
HEATER
23.95±15 Ω
MEASURE JUST ON THE COMPONENT
DETERGENT DISPENSER
1660 Ω ± %10 (25 C º)
MEASURE JUST ON THE COMPONENT
CIRCULATION PUMP
CN2.3 – CN2.9 95 ±%7 Ω
126 ±% 7 Ω
Primary winding
Secondary winding (FROM THE
COMPONENT)
SET NTC SENSOR
CN 3.2 25°- 5000Ω %±5.0
CN 3.1 35°- 3300Ω %±5.5
55°- 1520Ω %±6.5
63°- 1174Ω %±7.5
80°- 670Ω %±8.0
90°- 488Ω %±8.5
FAN MOTOR
CN 2.6 – CN 2.9 238.6 ± % 5
DIVERTER
CN 6.1 – CN 2.9 6840 ± % 5
RINSE AID SENSOR
CN 5.3 – CN5.2 0 Ω
∞ Ω
RINSE AID OFF
RINSE AID ON
FLOATER (MICROSWITCH )
CN2.1 – CN 2.5 0 Ω
CN2.1 – CN 2.4 ∞ Ω
MICROSWİTICH IS INACTİVE (NO
WATER)
MİKROSWITCH IS ACTIVE (THERE İS
WATER )
53