Failure Codes : C1 Models
ERROR CODE
Wash End Start
/Pause
ERROR
DESCRIPTION
POSSİBLE PROBLEMS
Inadequate
water supply
Make sure the water input tap is totally open and that there
is no water cut.
Close the water input tap, separate the water input hose
from the tap and clean the filter at the connection end of
the hose.
.Water inlet valve filter can be
Water inlet valve can be out of order
There can be a problem with the cable connection of water
inlet valve.
Floater switch can be out of order or have a problem with
the cable connection.
Pressure switch of the heater casing group can have a
mechanical or cable connection problem.
Circulation pump can be out of order or have a problem
with the cable connection.
Electronic card can be out of order.
Error of
continuous water
input
Water inlet valve can be out of order or can not be
closed.
Electronic card can be out of order.
The waste water
in the machine
cannot be
discharged.
Water outlet hose is clogged.
Water discharge hose can be out of order.
There can be a problem with cable connection of the drain
pump.
Pressure switch of the heater casing group can have a
mechanical or cable connection problem.
Electronic card can be out of order.
Intended water
temperature
could not be
reached/ faulty
heater and/or
heater sensor
NTC can be out of order.
Faulty NTC cable connection can be faulty. NTCshort or
open circuit.
Thermal protection can be out of order.
Heater can be out of order or cable connection can be out
order.
Alarm is active
against water
overflow
There can be a water leakage from the tub.
Floater switch can be out of order or have a problem with
the cable connection.
Electronic card can be out of order.
Electronic card
parameter faulty
By the Immediate and continuous voltage decreases
software variants can not be kept in the memory of
electronic card.
Faulty
Flowmeter
Cable connection of flowmeter can be faulty.
Electronic card can be out of order.
Door is open
Door lock mechanism can be out order.
There can be o problem with the cable connection of door
lock.
Electronic card can be out of order.
11