MAGIC 5. SERVICE PROGRAMME
Saeco International Group REV.5 SEPT.2004 Page 9/24
Display in test mode:
Upper display line:
Indicates the status of the microswitch (see table).
Lower display line:
Indicates the status of the operating buttons.
Grinder rate
If no button is activated, a three-digit number appears bottom right referring to the grinder
rate. This value must be between 125 - 135.
Flow rate
If the pump is activated during test mode and the hot water valve opened, a two-digit number
appears bottom right indicating the flow rate. This value must be between 40 - 60 (should not
be below 40).
All CPU input signals from the machine
appear in the first line of the display.
All CPU input signals from the control board
appear in the second line of the display.
Magic Comfort
Magic Comfort RD
1 = Brewing unit in brewing position
1 = Expresso lungo
1 = Expresso lungo
(brewing unit microswitch activated)
2 = Coffee
2 = Coffee
2 = Brewing unit in at-rest position
(at-rest position microswitch activated)
3 = Expresso
3 = Expresso
3 = Doser chamber full
4 = Powder coffee
4 = Powder coffee
(doser microswitch activated)
5 = Steam
5 = Steam
4 = HWS valve microswitch activated
6 = Standby
6 = Menu
5 = grinds container microswitch activated
6 = brewing unit microswitch activated
7 = Water tank filled
(reed contact not activated)
8 = Flow meter pulse system 1 (Water)
(indicator flashes when magnet passes
Hall generator)
Exit: Switch the machine off at the main switch.
1 2 3 4 5 6 7 8