MAGIC 5. SERVICE PROGRAMME
Saeco International Group REV.5 SEPT.2004 Page 3/24
2.2. Diagnosis menu (diagnosis box)
Application of diagnosis system
The diagnosis system makes it possible to read data and enter settings into the coffee machine without
the display.
ATTENTION: Before connecting the diagnosis box, it is important to ensure that you have read
the operating instructions.
Programme table (diagnosis menu)
Function/Standard
Setting range
Increment
Comments
EXPRESSO LUNGO
No. PULSES 600
50 - 1,000 Pulses
+/- 1
EXPRESSO
No. PULSES 195
50 - 1,000 Pulses
+/- 1
COFFEE
No. PULSES 360
50 - 1,000 Pulses
+/- 1
Number of flow meter pulses for
each saved cup fill volume, where
300 pulses correspond to approx.
100 ml.
----HEATING----
PARAMETER K1 7
1 - 50 +/- 1
Do not change!
----HEATING----
PARAMETER K2 30
1 - 50 +/- 1
Do not change!
NORMAL TEMP.
°C 86
70- 130°C +/- 1 Normal temperature is used if not
more than 6 min. have elapsed
since last coffee dispensed.
HIGH TEMP.
°C 92
70- 130°C +/- 1 If no coffee is dispensed for an
extended time (over 6 min.), the
next coffee will be heated to a
higher temperature to compensate
for cooling of the brewing unit and
the associated temperature loss.
TEMP. OF 1st
COFFEE
° C 94
70- 130°C +/- 1 Used when dispensing the first
coffee after the machine has been
turned on, to compensate for the
high temperature loss due to the
cold brewing unit and water pipes.
STEAM TEMP.
°C 130
70- 135°C +/-1 Boiler temperature for steam
function.
TEMP. INCREASE
°C 10
0-50°C +/-1 The boiler temperature is increased
by a set value shortly before
brewing in order to pre-heat the
boiler, and compensate for the
temperature drop during the first
water flow.