MAGIC 5. SERVICE PROGRAMME
Saeco International Group REV.5 SEPT.2004 Page 11/24
Parameter /RD
Setting range
Increment
Comments
TEMP. OF 1st
COFFEE
° C 94/99
70- 130°C +/- 1 Used when dispensing the first
coffee after the machine has been
turned on, to compensate for the
high temperature loss due to the
cold brewing unit and water pipes.
STEAM TEMP.
°C 130/125
70- 135°C +/-1 The temperature for steam
operation is entered separately
using the Steam Temp. parameter.
TEMP. INCREASE
°C 10
0-50°C
Not for RD model
+/-1 The boiler temperature is increased
by a set value shortly before
brewing in order to pre-heat the
boiler and compensate for the
temperature drop during the first
water flow.
GRINDS COUNTER
Number
0-50 +/-1 Counts number of coffee cycles.
When this value reaches the
Grinds Stop value, "GRINDS
CONTAINER EMPTY" will be
displayed. (Reset by removing
dregs drawer for emptying - min. 6
sec.)
GRINDS STOP
30
5-50 +/-1 Number of cycles until "EMPTY
GRINDS CONTAINER" is
displayed.
--TOTAL WATER--
(ml) Number
--------------------- -----------------
------
Total water flow volume (in ml) /
not resettable
WATER DESCALING
(ml)
--------------------- -----------------
------
Total water flow (in ml) since last
descaling / resettable
HOT WATER
FLOW (L/H)
20/16
6 - 34 1/h
+/- 2 1/h The pump delivery rate for hot
water can be expressed in litres per
hour.
--HOT WATER---
PUMP ADJUST. 63000
58,000 - 65,500 +/- 1 The pump delivery rate is adjusted
in relation to the HOT WATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under HOT WATER PUMP
ADJUSTMENT.