5. SERVICE PROGRAMME MAGIC
Page 24/24 REV.5 SEPT.2004 Saeco International Group
d. Init. intern:
This function indicates the standard values of the internal data set. These must be checked and adapted
to the current production values.
e. Corrections:
The number of independently performed programme corrections in EEPROM can be called up here.
The EEPROM machine corrections appear first and when a button is pressed, the internal EEPROM
corrections are displayed. Press the button again to exit. If the machine is not connected to the diagnosis
device, only the internal EEPROM corrections are shown.
f. Exit:
Use the SAVE button to exit the submenu without recalling the function.
6.3.7. Printing
Use the PRINT MACHINE DATA button to print all machine data (only when the machine is
connected). The data of the internal data set can be printed by pressing the PRINT INTERN DATA
button.
6.3.8. Paper load
The diagnosis device must be connected in order to load the paper. After connecting the diagnosis
device, press the LINE FEED button. As the printer operates, the paper is drawn into the paper slot. As
soon as the printer is able to draw the paper independently, the paper is released. Release the LINE
FEED button when about 5 mm of the paper is visible.
ATTENTION: Only special thermopaper 37 mm wide can be used. The paper can only be printed
on one side. The printing head can be damaged if the printer is started without paper. Therefore,
before commencing a print run, check that there is sufficient paper. The end of the paper roll is
indicated with a red stripe running along the paper.

Table of Contents

Related product manuals