MAGIC 6. FAULTS
Saeco International Group REV.5 SEPT.2004 Page 1/3
1. Faults:
The following table indicates the most common faults, listed by component.
Part Fault Cause
SI on mains filter (Magic old)
defective
SI on electronic system (Magic
Silicone) defective
Electronic system defective
Door switch defective
Electronics
Do not function
Indicator light contactor does not turn
on (no display)
Main switch defective
KTY defective Cold coffee
Standby LED lights up continuously
Electronic system defective
KTY defective Temperature differences
No froth
Electronic system defective
Heating - Interruption
Heating plug connection
Thermal fuse
Heating system
Heating remains cold
Standby LED does not light up
Fusible cut-out
(No grinder function)
Doser switch constantly
activated / Dirt
Water instead of coffee
Defective doser rinse
Dose quantity too low Weak coffee
Dose chamber - coffee residues
Doser switch does not work
Electronic system defective
Doser
Fault LED (coffee beans low) lights
up constantly
- Brewing unit overfull
- Gearmotor obstructed