14
SafeLine MX2 v.5.2.1 EN
Conguration
examples
Example 2: SLCC (SafeLine Call Centre) and 3-day test.
1. Startconguration:
0 0
2. Enter P100 ID code:
* 0 1 * 4 5 6 4 5 6 4 5 #
Lift ID code (each lift must have its own unique code).
3. Set test alarm type:
* 3 1 * 0 #
4. Set number of days between test alarm:
* 2 7 * 0 3 # - Example: 3 days between test alarm.
5. LMS phone number:
*16*98765432#
(Only if using SLCC)
6. Test alarm:
* 1 7 * 1 2 3 1 2 3 1 2 #
(For P100 use telephone number of SLCC, for Caller ID set
*31*4# and telephone number of GSM modem)
7. Endconguration:
* 0 0 * #
If at any time you need to
start over, use the factory
resetcommand*99*1#.
Please refer to the full
congurationsetupinthe
“Parameter list” as these are
merely examples.